P-Value Adjustment Calculator: Bonferroni, Holm and FDR (Benjamini–Hochberg)
Ran many tests? Paste your p-values (with labels if you like) and get adjusted p-values for every common multiple-testing correction, which results stay significant, a plot and a sentence for your methods section. Results match R’s p.adjust().
- PriceFree, no login or sign-up needed
- Your dataProcessed in your browser, never uploaded
- Works onPhone, tablet or computer, any modern browser
- Made byDr. Muhammad Aammar Tufail, Codanics
- Published16 November 2026
- Last updated16 November 2026
📚 How to cite this tool
This tool is free. If it helped your thesis, paper, report or assignment, please cite it. It keeps the tools free and helps other students find them.
Tufail, M. A. (2026). P-value adjustment calculator [Online tool]. Codanics. Retrieved 16 November 2026, from https://codanics.com/tools/p-value-adjustment-calculator/
In-text citation: (Tufail, 2026) · Narrative: Tufail (2026)
The access date is today’s date, filled in automatically. Author: Muhammad Aammar Tufail. Published 16 November 2026.
How to use the p-value adjustment calculator
- Paste your p-values, one per line. Add a label before each value (for example
Root length, 0.021) to keep track of which test is which, or load a spreadsheet column with Paste from Excel or Upload CSV / Excel. - Choose α and tick the correction methods you want to compare. Pick the method you will report under Method for the sentence.
- Click Adjust p-values. Green cells are still significant after correction.
- Copy the table or download the CSV with full precision, copy the sentence for your methods section and download the plot if you need it.
Which correction should I use?
| Method | Controls | Use when |
|---|---|---|
| Holm | Family-wise error rate (FWER) | A handful of planned tests, e.g. several outcomes or pairwise comparisons. Always at least as powerful as Bonferroni, with no extra assumptions. A safe default. |
| Bonferroni | FWER | Simple and widely understood, but conservative. Fine for a few tests; wasteful for many. |
| Šidák | FWER | Slightly less conservative than Bonferroni when tests are independent. |
| Hochberg / Hommel | FWER | More powerful than Holm, but valid only when tests are independent or positively correlated. Hommel is the most powerful of the FWER methods. |
| Benjamini–Hochberg (BH) | False discovery rate (FDR) | Many tests in exploratory work: genes, metabolites, OTUs, many traits or correlations. You accept a small proportion of false positives to find more true effects. |
| Benjamini–Yekutieli (BY) | FDR under any dependence | Like BH but valid for any correlation between tests. Much more conservative. |
How the adjusted p-values are calculated
With m tests and p-values sorted from smallest, p₍₁₎ ≤ … ≤ p₍ₘ₎:
A test is significant after correction if its adjusted p-value is below α. All values match R’s p.adjust() exactly, so you can reproduce them with p.adjust(p, method = "holm").
Adjusted p-values, FDR and q-values
A BH-adjusted p-value is often called an FDR-adjusted p-value or, loosely, a q-value. If you call everything with a BH value below 0.05 significant, you expect about 5% of those findings to be false positives. Storey’s q-value (the R package qvalue) is a related but different quantity: it also estimates the proportion of true null hypotheses and is usually a little smaller than the BH value. Say which one you used.
How to report it
“P-values were adjusted for multiple comparisons using the Holm method. After adjustment, 3 of 12 traits differed significantly between treatments (adjusted p < .05).” In tables, report the adjusted p-values and say so in the column heading or a footnote. For pairwise comparisons after ANOVA, a post-hoc test such as Tukey’s HSD in the one-way ANOVA calculator is usually better than adjusting t-tests by hand.
Frequently asked questions
What is the difference between Bonferroni and Holm?
Both control the family-wise error rate, but Holm adjusts step by step from the smallest p-value. It never finds fewer significant results than Bonferroni and often finds more, with no extra assumptions, so Holm is generally preferred.
When should I use FDR (Benjamini–Hochberg) instead of Bonferroni?
Use FDR when you run many tests in exploratory research, such as gene expression, metabolomics or screening many traits, and can accept a small proportion of false positives. Use FWER methods such as Holm or Bonferroni for a few confirmatory tests where any false positive is costly.
Is a BH-adjusted p-value the same as a q-value?
Often the terms are used interchangeably, but strictly a q-value (Storey’s method) also estimates the share of true null hypotheses and is usually slightly smaller. This tool gives BH-adjusted p-values, which match p.adjust(p, ‘BH’) in R.
How many tests count as 'm'?
Count every test in the family you are drawing a conclusion from, including the non-significant ones. Do not drop tests before adjusting, or the correction will be too lenient.
Do I need to adjust p-values after ANOVA?
For pairwise comparisons after ANOVA, use a dedicated post-hoc test such as Tukey’s HSD, which already controls the error rate. Adjusting p-values is for situations where you ran several separate tests yourself.
Are my p-values sent anywhere?
No. Everything is calculated in your browser and nothing is uploaded or stored.
Do I need to log in or create an account to use the p-value adjustment calculator?
No. There is no login, no sign-up and no email required. Open the page and start using it straight away, for free, on any device.
How do I cite this tool in my thesis or paper?
Use the citation box on this page. In APA 7th edition: Tufail, M. A. (2026). P-value adjustment calculator [Online tool]. Codanics. Retrieved [date you used it], from https://codanics.com/tools/p-value-adjustment-calculator/. BibTeX, RIS (EndNote, Mendeley, Zotero), MLA, Harvard, Chicago and Vancouver formats are also available.
Free guides and courses from Codanics
More free tools
See all free Codanics tools → · Codanics on YouTube · WhatsApp channel