Dilution Calculator: C1V1 = C2V2 and Serial Dilution Planner
Dilute a stock to a working solution or plan a whole serial dilution in seconds. Enter any three of C₁, V₁, C₂ and V₂ in the units you use (M, mM, mg/mL, ng/µL, 10X, %) and get the volume to pipette and the diluent to add. The serial dilution planner gives a tube-by-tube table and a diagram you can print.
- PriceFree, no login or sign-up needed
- Your dataProcessed in your browser, never uploaded
- Works onPhone, tablet or computer, any modern browser
- Made byDr. Muhammad Aammar Tufail, Codanics
- Published16 November 2026
- Last updated16 November 2026
📚 How to cite this tool
This tool is free. If it helped your thesis, paper, report or assignment, please cite it. It keeps the tools free and helps other students find them.
Tufail, M. A. (2026). Dilution calculator: C1V1 = C2V2 and serial dilution planner [Online tool]. Codanics. Retrieved 16 November 2026, from https://codanics.com/tools/dilution-calculator/
In-text citation: (Tufail, 2026) · Narrative: Tufail (2026)
The access date is today’s date, filled in automatically. Author: Muhammad Aammar Tufail. Published 16 November 2026.
How to use the dilution calculator
- For a single dilution, stay on C₁V₁ = C₂V₂, choose what to solve for (usually V₁, the volume of stock) and enter the other three values with their units.
- If the stock and target are in different kinds of units (for example mg/mL and µM), type the molecular weight so the calculator can convert.
- For a series, open Serial dilution planner, enter the stock, the fold per step (10 for 1:10), the number of tubes and either the transfer volume or the volume you want left in each tube.
- Copy the instructions or table, download the CSV, and print the tube diagram for the bench.
The C₁V₁ = C₂V₂ dilution formula
When you dilute a solution, the amount of solute stays the same; only the volume changes. So concentration × volume before equals concentration × volume after:
Worked example: to make 10 mL of 50 µg/mL from a 1 mg/mL (1,000 µg/mL) stock: V₁ = 50 × 10 ÷ 1000 = 0.5 mL (500 µL) of stock plus 9.5 mL of diluent. That is a 1:20 dilution.
How a serial dilution works
A serial dilution repeats the same dilution several times, each tube made from the one before. With a dilution factor f per step, tube n has a concentration of C₀ ÷ fⁿ. For a 10-fold series from 1 mg/mL the tubes are 100, 10, 1, 0.1 µg/mL and so on.
Serial dilutions are used for standard curves (ELISA, Bradford, qPCR), CFU counts in microbiology (10⁻¹ to 10⁻⁸ before plating), MIC tests for antibiotics (two-fold series) and dose–response experiments.
Tips for accurate dilutions
- Use a fresh tip for every transfer and mix thoroughly before taking the next aliquot.
- Avoid pipetting less than 1–2 µL; make an intermediate dilution instead.
- For very large dilutions (over 1:1000), two or three serial steps are more accurate than one.
- Prepare a little extra volume so you never run short at the last tube.
- To prepare the stock itself from a powder, use the molarity calculator.
Frequently asked questions
How do I use C1V1 = C2V2?
Write the stock concentration (C1), the target concentration (C2) and the final volume (V2), then solve V1 = C2 × V2 ÷ C1. Pipette V1 of stock and add V2 − V1 of diluent. The units of C1 and C2 must match, and V1 comes out in the units of V2.
What is a 1:10 dilution?
One part of sample in a total of ten parts, for example 100 µL of sample plus 900 µL of diluent. Its dilution factor is 10. Note that some fields use 1:10 to mean 1 part plus 10 parts; this calculator uses 1 part in 10 total.
How do I make a 10-fold serial dilution?
Put 900 µL of diluent in each tube. Add 100 µL of stock to tube 1 and mix, then move 100 µL from tube 1 to tube 2, and so on. Each tube is ten times more dilute than the one before.
Can I dilute from mg/mL to µM?
Yes, if you give the molecular weight. The calculator converts mass concentration to molar concentration (mg/mL ÷ MW × 1000 = mM) before solving.
Why does the calculator refuse my units?
A concentration in % v/v, fold (X) or mass units cannot be compared with molar units unless the molecular weight is known, and % v/v cannot be converted to mass units at all without density. Choose the same kind of unit for C1 and C2.
Is my data sent anywhere?
No. Everything is calculated in your browser and nothing is uploaded or stored.
Do I need to log in or create an account to use the dilution calculator?
No. There is no login, no sign-up and no email required. Open the page and start using it straight away, for free, on any device.
How do I cite this tool in my thesis or paper?
Use the citation box on this page. In APA 7th edition: Tufail, M. A. (2026). Dilution calculator: C1V1 = C2V2 and serial dilution planner [Online tool]. Codanics. Retrieved [date you used it], from https://codanics.com/tools/dilution-calculator/. BibTeX, RIS (EndNote, Mendeley, Zotero), MLA, Harvard, Chicago and Vancouver formats are also available.
Free guides and courses from Codanics
More free tools
See all free Codanics tools → · Codanics on YouTube · WhatsApp channel