Lab & life science

PCR Master Mix Calculator: Volumes per Reaction and for n Reactions

Set the reaction volume and number of reactions, adjust the stock and final concentrations of each component, and get the volume of each to pipette per reaction and for the whole master mix, with extra for pipetting loss. Presets for Taq, Phusion-type, ready-made 2X mixes and SYBR Green qPCR.

✅ No login needed100% freeRuns in your browserYour data stays on your device
PCR Master Mix Calculator✅ Free · no login📚 Cite this tool
Your data never leaves your PC. Your data is analysed on your own computer or phone, even when you upload a CSV or Excel file. Nothing is uploaded, stored or seen by Codanics, and no login is needed.
ComponentStockUnitFinalUnitIn master mixRemove
  • PriceFree, no login or sign-up needed
  • Your dataProcessed in your browser, never uploaded
  • Works onPhone, tablet or computer, any modern browser
  • Made byDr. Muhammad Aammar Tufail, Codanics
  • Published17 November 2026
  • Last updated16 November 2026

📚 How to cite this tool

This tool is free. If it helped your thesis, paper, report or assignment, please cite it. It keeps the tools free and helps other students find them.

Citation · APA 7th edition

Tufail, M. A. (2026). PCR master mix calculator: volumes per reaction and for n reactions [Online tool]. Codanics. Retrieved 16 November 2026, from https://codanics.com/tools/pcr-master-mix-calculator/

In-text citation: (Tufail, 2026) · Narrative: Tufail (2026)

The access date is today’s date, filled in automatically. Author: Muhammad Aammar Tufail. Published 17 November 2026.

🚀 Follow Codanics channel on WhatsApp for more updatesNew free tools, scholarships, PhD positions and research tips, straight to your phone. Free lessons on YouTube too.

How to use the pcr master mix calculator

  1. Pick a preset close to your kit (Taq, high-fidelity, ready-made 2X mix or SYBR Green qPCR), then set the reaction volume and the number of reactions, including negative and positive controls.
  2. Check each component’s stock and final concentration against your kit’s manual. Polymerase can be given in U per reaction; template in µL per reaction.
  3. Untick In master mix for anything you add to each tube separately (usually the template).
  4. Make the master mix from the right-hand column, dispense the per-tube volume and add the template. Copy the recipe into your lab notebook.

How the master mix is calculated

volume per reaction = final concentration × reaction volume ÷ stock concentration polymerase volume = units per reaction ÷ stock (U/µL) water = reaction volume − sum of all other volumes master mix volume = per-reaction volume × n × (1 + extra %)

Worked example (25 µL Taq PCR): 10X buffer to 1X = 2.5 µL; 25 mM MgCl₂ to 1.5 mM = 1.5 µL; 10 mM dNTPs to 0.2 mM = 0.5 µL; 10 µM primers to 0.4 µM = 1.0 µL each; 5 U/µL Taq for 1.25 U = 0.25 µL; template 1 µL; water 17.25 µL. For 24 reactions + 10% (26.4), the master mix has 455.4 µL water, 66 µL buffer, 39.6 µL MgCl₂, 13.2 µL dNTPs, 26.4 µL of each primer and 6.6 µL Taq; dispense 24 µL per tube and add 1 µL template.

Typical final concentrations

ComponentTypical finalNotes
Buffer1XCheck whether it already contains Mg²⁺
MgCl₂1.5–2.5 mMHigher Mg raises yield but lowers specificity
dNTPs200 µM each“10 mM dNTP mix” usually means 10 mM of each
Primers0.1–0.5 µM each0.2–0.4 µM is typical for qPCR
Taq polymerase1–1.25 U per 25–50 µLFollow the supplier for high-fidelity enzymes
Template1–100 ng genomic DNA; 0.1–1 ng plasmidToo much template inhibits PCR
Always make about 10% extra (or 1–2 extra reactions) because liquid is lost on pipette tips, and include a no-template control. Need primer Tm and annealing temperature? Use the primer Tm calculator.
Learn the statistics behind these numbers. Codanics has free statistics, R and Python lessons on YouTube and full courses for researchers.

Frequently asked questions

How do I calculate a PCR master mix?

Work out the volume of each component for one reaction (final concentration × reaction volume ÷ stock concentration), fill the rest with water, then multiply every volume by the number of reactions plus about 10% extra.

How much extra master mix should I make?

About 10% extra, or one extra reaction per 10, covers pipetting loss. With many reactions (a 96-well plate) 5% is usually enough.

What final primer concentration should I use?

0.1–0.5 µM of each primer is typical; 0.2–0.4 µM for SYBR Green qPCR. From a 10 µM stock, 0.4 µM in 25 µL needs 1 µL.

How many units of Taq polymerase per reaction?

Usually 0.5–1.25 units per 25 µL reaction (1.25 units per 50 µL for many suppliers). With 5 U/µL Taq, 1.25 U is 0.25 µL, which is why it is best added to a master mix rather than to each tube.

Should the template go into the master mix?

Usually not. Add the template to each tube separately so that every sample gets its own DNA. Untick “In master mix” for the template row.

Is my recipe stored or uploaded?

Nothing is uploaded. If you click “Save as my recipe”, it is kept only in this browser’s local storage.

Do I need to log in or create an account to use the pcr master mix calculator?

No. There is no login, no sign-up and no email required. Open the page and start using it straight away, for free, on any device.

How do I cite this tool in my thesis or paper?

Use the citation box on this page. In APA 7th edition: Tufail, M. A. (2026). PCR master mix calculator: volumes per reaction and for n reactions [Online tool]. Codanics. Retrieved [date you used it], from https://codanics.com/tools/pcr-master-mix-calculator/. BibTeX, RIS (EndNote, Mendeley, Zotero), MLA, Harvard, Chicago and Vancouver formats are also available.

Free guides and courses from Codanics

More free tools

See all free Codanics tools → · Codanics on YouTube · WhatsApp channel

Made by Dr. Muhammad Aammar Tufail, Codanics. First published 17 November 2026, last updated 16 November 2026. Found a bug or have an idea for a new tool? Tell us on the WhatsApp channel or in the comments on YouTube. Results are for learning and planning; check important analyses with a statistician or your supervisor.