Cell Counting and Seeding Calculator: Haemocytometer, Viability and Plating Volumes
Type the live and dead cells you counted in each square of the haemocytometer and get cells/mL, viability, total cells and a 95% confidence interval. Then plan seeding: cells per well or per cm² for any plate or flask, with the volume of suspension and medium to mix.
- PriceFree, no login or sign-up needed
- Your dataProcessed in your browser, never uploaded
- Works onPhone, tablet or computer, any modern browser
- Made byDr. Muhammad Aammar Tufail, Codanics
- Published17 November 2026
- Last updated16 November 2026
📚 How to cite this tool
This tool is free. If it helped your thesis, paper, report or assignment, please cite it. It keeps the tools free and helps other students find them.
Tufail, M. A. (2026). Cell counting and seeding calculator: haemocytometer, viability and plating volumes [Online tool]. Codanics. Retrieved 16 November 2026, from https://codanics.com/tools/cell-counting-calculator/
In-text citation: (Tufail, 2026) · Narrative: Tufail (2026)
The access date is today’s date, filled in automatically. Author: Muhammad Aammar Tufail. Published 17 November 2026.
How to use the cell counting and seeding calculator
- Load the haemocytometer with cells mixed with trypan blue and count the live (clear) and dead (blue) cells in each large square, usually the 4 corner squares.
- Type the counts for each square, choose the square size and enter the dilution factor (2 for a 1:1 mix with trypan blue).
- Read the live cells/mL, viability and confidence interval, then click Plan seeding.
- Choose the plate or flask, the number of cells per well (or per cm²), the number of wells and the medium volume, and mix the suspension and medium as shown.
Haemocytometer formula
Each large corner square of an improved Neubauer chamber is 1 mm × 1 mm × 0.1 mm deep, which holds 0.1 µL (10⁻⁴ mL). So:
Worked example: 52, 47, 55 and 49 live cells (mean 50.75) and 18 dead cells in 4 squares, diluted 1:1 with trypan blue: 50.75 × 2 × 10⁴ = 1.02 × 10⁶ live cells/mL; viability = 203 ÷ 221 = 91.9%. In 5 mL there are 5.08 × 10⁶ live cells.
How accurate is a haemocytometer count?
Cell counts follow a Poisson distribution, so the counting error is about 1/√N for N cells counted: about 10% for 100 cells and 7% for 200. The calculator gives an exact Poisson 95% confidence interval and tests whether the squares differ more than chance (a sign of clumping or poor mixing).
Seeding cells
| Vessel | Growth area (cm²) | Typical medium (mL) |
|---|---|---|
| 96-well plate | 0.32 | 0.1–0.2 |
| 24-well plate | 1.9 | 0.5–1 |
| 12-well plate | 3.8 | 1–2 |
| 6-well plate | 9.5 | 2–3 |
| T25 / T75 flask | 25 / 75 | 5 / 15 |
Frequently asked questions
How do I calculate cells/mL from a haemocytometer?
Average the cells counted in the large squares, multiply by the dilution factor and by 10⁴. For example, a mean of 40 cells per square with a 1:1 trypan blue dilution is 40 × 2 × 10⁴ = 8 × 10⁵ cells/mL.
How do I calculate cell viability with trypan blue?
Viability = live (unstained) cells ÷ (live + dead blue cells) × 100. Count both in the same squares.
How many squares should I count?
Count enough squares to reach at least 100–200 cells, usually the 4 corner squares (or all 9 for sparse samples). Count both chambers and average them for important experiments.
How do I calculate the volume of cells to seed?
Multiply the cells per well by the number of wells (plus about 10% extra), divide by your cells/mL, and make up to the total medium volume. The seeding tab does this for any plate or flask.
Which cells on the lines should I count?
Use a fixed rule, such as counting cells touching the top and left lines but not the bottom and right lines, so that no cell is counted twice.
Is my data sent anywhere?
No. All calculations run in your browser and nothing is uploaded.
Do I need to log in or create an account to use the cell counting and seeding calculator?
No. There is no login, no sign-up and no email required. Open the page and start using it straight away, for free, on any device.
How do I cite this tool in my thesis or paper?
Use the citation box on this page. In APA 7th edition: Tufail, M. A. (2026). Cell counting and seeding calculator: haemocytometer, viability and plating volumes [Online tool]. Codanics. Retrieved [date you used it], from https://codanics.com/tools/cell-counting-calculator/. BibTeX, RIS (EndNote, Mendeley, Zotero), MLA, Harvard, Chicago and Vancouver formats are also available.
Free guides and courses from Codanics
More free tools
See all free Codanics tools → · Codanics on YouTube · WhatsApp channel